Northern Comfort Heating & Cooling
Boiler InspectionDraft Hood Boiler - Health Assessment Report
CustomerBrookside Apartments
Service address210 Hunter Street East, Peterborough, ON
Date of serviceOctober 5, 2026
TechnicianAlex Morgan
EquipmentGas boiler - Weil-McLain CGa-5
SerialWM-440912
Installed2011-10
Filter size / Report #- / FC-3
Checkup score89%Grade B+

Operating, attention recommended

Your boiler is operating, but our technician recommends attention to the items listed in the report.

20 checked1 needs attention
Boiler Health Assessment
Controls & Safety
Are the safety controls working?
Controls and safety devices tested
Water & Pressure
Is the water side sound and at the right pressure?
Review recommended: 1 item flagged. See details below.
Circulation
Is hot water moving around the system?
Circulators and zone valves checked
Burner & Heat Exchanger
Are the burners and heat exchanger clean and sound?
Burners and heat exchanger cleaned and inspected
Venting & Draft Hood
Is exhaust leaving your home safely?
Draft hood, spillage test and venting inspected
Gas & Combustion
Is the gas supply tight and burning cleanly?
Gas piping and combustion analysis completed
Safety Testing
Is the air in your home safe?
Carbon monoxide checked and alarm present
Good Review recommended Action needed Not checked

From your technician

The boiler is operating safely and heating well. The draft hood, vent connector and chimney were inspected with no spillage. We recommend replacing the pressure relief valve at the next visit.
Alex Morgan, Northern Comfort Heating & Cooling

What we recommend

In order of priority. Nothing is done without your approval.

Recommended soon$285
Replace the pressure relief valve (weeping at the seat).

The full checklist

1

Controls & Safety

Aquastat, limits, low-water cut-off and safeties

Check operation of thermostat, aquastat and high limit
Checked
Test low water cut-off (if equipped)
Checked
Check flame rollout and vent safety switches (if equipped)
Checked
Check pilot / ignition and flame safety controls
Checked
2

Water & Pressure

System pressure, relief valve, expansion tank and leaks

Inspect pressure relief valve and discharge pipe; test lever
Relief valve is weeping slightly - replace at next visit.
Needs attention
Check pressure / temperature gauge
Checked
Check expansion tank and air elimination; system water pressure correct
Checked
Check fill valve / backflow preventer; no leaks at boiler or piping
Checked
3

Circulation

Circulator pumps and zone valves

Check circulator pump(s) and zone valves; lubricate as required
Checked
4

Burner & Heat Exchanger

Burners, flame and heat exchanger

Clean burners; check flame pattern and colour
Checked
Inspect and clean heat exchanger and flue passages
Checked
Clean boiler exterior; check jacket and insulation
Checked
5

Venting & Draft Hood

Draft hood, spillage test, vent and chimney

Inspect draft hood: correctly installed, clear, no soot, rust or backdrafting marks
Checked
Spillage / draft test completed (flue gases pulled up the vent)
Checked
Inspect vent connector: slope, joints, support and clearances
Checked
Inspect chimney / liner and termination
Checked
Combustion / ventilation air adequate
Checked
6

Gas & Combustion

Gas piping and combustion analysis

Check gas piping and shutoff valve; leak test completed
Checked
Combustion analyzer test completed
Checked
7

Safety Testing

Carbon monoxide and alarms

Check ambient air for elevated CO levels
Ambient CO reading: 0 ppm
Checked
Carbon monoxide alarm present and working
Checked

Measurements

Readings taken by your technician during the visit.

Water pressure in the system15 psi
Typical: about 12 to 25 psi
Carbon monoxide in room air0 ppm
Typical safe level: under 9 ppm
Water temperature drop22°FSupply minus return water
System water pressure15psi
Supply water temperature178°F
Return water temperature156°F
Gas inlet pressure7.0in. w.c.
Gas manifold pressure3.5in. w.c.
CO in flue gas22ppm
CO₂9.1%
O₂4.8%
Flue gas temperature312°F
Combustion efficiency82%
Draft at the hood-0.03in. w.c.
Your next checkupOctober 2027
Regular maintenance keeps your equipment efficient and safe.

About this service

A yearly boiler service cleans the burners and heat exchanger, tests the safety controls and relief valve, checks the water pressure and circulator, and confirms the draft hood and venting carry exhaust safely out of the home.

Why every year?

A boiler heats your home and holds water under pressure, so small problems matter. Dirty burners, a blocked flue, a weak relief valve or low system pressure can mean a breakdown, higher fuel bills or a safety risk. On a draft hood boiler, a yearly spillage and venting check is the key safety test. A yearly service keeps a written record that the boiler has been properly maintained.

Your score is based on how many inspection items passed without needing attention. Comparing it year to year shows how your equipment is holding up.

Northern Comfort Heating & Cooling