EquipmentOil furnace - Beckett / Thermo Pride AFG burner
SerialTP-88213
Installed2008-09
Filter size / Report #20x20x1 / FC-2
Checkup score98%Grade A+
Operating normally
Your oil furnace is operating normally.
25 checked1 needs attention
Oil Furnace Health Assessment
Controls & Safety
Are the controls and safety devices working?
Controls, safety shutoff and alarms checked
Burner & Fuel
Is the burner clean and the fuel system tight?
Burner serviced, wear parts replaced, oil lines checked
Airflow
Is your furnace moving air the way it should?
Blower and belt checked and serviced
Filtration
Is the air filter clean and the right size?
Review recommended: 1 item flagged. See details below.
Heat Exchanger
Is the heating section clean and sound?
Combustion chamber and heat exchanger cleaned and inspected
Venting
Is exhaust leaving your home safely?
Flue pipe, damper and chimney inspected
Safety Testing
Is the burner tuned and the air safe?
Carbon monoxide and combustion tests completed
Good Review recommended Action needed Not checked
From your technician
Nozzle, filter and electrodes replaced, burner head and heat exchanger cleaned, and the oil line and tank checked. Combustion readings are on target.
Alex Morgan, Northern Comfort Heating & Cooling
What we recommend
In order of priority. Nothing is done without your approval.
Keep an eye on it
Oil tank is over 15 years old - plan to inspect or replace within the next few years.
The full checklist
1
Controls & Safety
Thermostat, safety limits, flame safety shutoff and alarms
Check operation of thermostat
Checked
Check operation of safety limit controls
Checked
Test flame-failure safety shutoff (cad cell / primary control lockout)
Checked
120 Volt System
Checked
24 Volt Control Side
Checked
Carbon monoxide and smoke alarms present and working
Checked
2
Burner & Fuel
Nozzle, filter, electrodes, pump and oil lines
Replace oil nozzle
Checked
Replace oil filter / clean strainer
Checked
Clean and set electrodes; check ignition transformer
Checked
Clean burner head, air tube, turbulator and air band
Checked
Check fuel pump pressure and cut-off
Checked
Lubricate burner motor and furnace motor bearings as required
Checked
Inspect oil lines, fittings and fire valve for leaks
Checked
Oil tank and supply visually checked (see Aboveground Oil Tank Inspection)
Checked
3
Airflow
The parts that move warm air through your home
Remove and clean motor and blower assembly
Checked
Check blower operation
Checked
Check condition, tension and alignment of fan belt
Checked
4
Filtration
Keeping dust and debris out of your system
Clean or replace air filters and instruct customer on filter maintenance
Replaced.
Needs attention
5
Heat Exchanger
Where your furnace makes and transfers heat
Inspect and clean heat exchanger and flue passages
Checked
Inspect and clean combustion chamber / refractory
Checked
Clean equipment exterior
Checked
6
Venting
Getting exhaust safely out of your home
Inspect flue pipe, barometric damper and connections
Checked
Visually inspect chimney and liner
Checked
Combustion/ventilation air adequate
Checked
7
Safety Testing
Carbon monoxide and combustion analysis
Check ambient air for elevated CO levels
Ambient CO reading: 0 ppm
Checked
Combustion analyzer test completed (burner cover on)
Checked
Measurements
Readings taken by your technician during the visit.
Smoke test (how clean the flame burns)1
Target: a slight trace, 0 to 1 on the smoke scale
Carbon dioxide in flue gas (burner tuning)12.4 %
Typical for oil: about 11 to 13.5%
Combustion efficiency85 %
Typical: low 80s or better
Carbon monoxide in room air0 ppm
Typical safe level: under 9 ppm
Airflow resistance (external static pressure)0.38 in. w.c.
Typical range: 0.1 to 0.5 in. w.c.
Temperature rise71°FSupply minus return air
Nozzle installed (GPH x angle)0.75 / 70B
Fuel pump pressure140psi
Breech draft (target about -0.01)-0.04in. w.c.
Smoke number (0 to 9)1
CO in flue gas31ppm
CO in flue gas, air-free42ppm
CO₂12.4%
O₂3.9%
Excess air22%
Stack temperature372°F
Ambient temperature64°F
Net stack temperature308°F
Combustion efficiency85%
Supply air temperature142°F
Return air temperature71°F
External static pressure0.38in. w.c.
Your next checkupOctober 2027
Regular maintenance keeps your equipment efficient and safe.
About this service
A yearly oil furnace service replaces the parts that wear, cleans the burner, combustion chamber and flue passages, and sets the burner up with a combustion analyzer. A clean, properly tuned oil burner runs more efficiently, makes less soot and keeps your home safer.
Why every year?
Oil burners collect soot, and nozzles, filters and electrodes wear out. Left alone, that means higher fuel bills, smoke or odour, and a no-heat call on the coldest night. A yearly service catches small problems early and keeps a record of each visit. Think of it like a yearly physical for your heating system.
Your score is based on how many inspection items passed without needing attention. Comparing it year to year shows how your equipment is holding up.